1. Product Overview & Market Advantages
As a clean energy source with a high calorific value and low environmental impact, Natural Gas has become a global standard for sustainable power. Liquefied Natural Gas (LNG) offers significantly higher volumetric energy density and transport efficiency per vehicle compared to Compressed Natural Gas (CNG).
The LNG Tank Container (hereinafter referred to as the “LNG Tank”) delivers exceptional mobility and flexibility. It is designed for seamless intermodal transportation across road, rail, and water, making it the premier logistical solution for bulk cryogenic gas distribution.
2. Structural Features
The LNG Tank features a highly engineered, robust architecture divided into three primary systems:
- Storage Vessel: A double-walled, vacuum-insulated inner tank designed for extreme cryogenic temperatures.
- Structural Frame: Connected to the storage tank via high-strength short semi-cylinders, strip supports, and specialized steel piping to ensure maximum structural integrity during transit.
- Integrated Operation Box: Centrally located at one end of the container, housing all critical control valves, instrumentation, and safety relief devices to ensure streamlined, safe loading and unloading operations.
3. Technical Specifications
- Design & Operating Parameters
| Parameter | Inner Vessel | Outer Jacket |
| Material of Shell | SA-240M 304 (Stainless Steel) | Q345R (Carbon Steel) |
| Maximum Allowable Working Pressure (M.A.W.P.) | +0.80 / -0.04 MPa | -0.103 MPa |
| Minimum Design Metal Temperature (MDMT) | -196 ℃ | -40 ℃ |
| Design Temperature Range (Max / Min) | -196 ℃ / +50 ℃ | -40 ℃ / +50 ℃ |
| Nominal Shell Thickness | 6 mm | 4 mm |
| Required Head Thickness | 7 mm | 5 mm |
| Full Capacity (±1%) | 45.7 m³ | 7.89 m³ (Insulation Interspace) |
- Testing, Compliance & Surface Treatment
| Technical Item | Specification / Requirement |
| ASME Certification Mark Stamping | Yes (Required for Inner Vessel) |
| National Board (NB) Registration | Not required |
| Pressure Test | 1.17 MPa (Hydrostatic/Pneumatic at 4 ~ 48 ℃) |
| Leak & Vacuum Testing | Helium Leakage Checked (Inner & Outer) |
| Inner Surface Treatment | Pickling & Passivation (Oil content ≤ 25 mg/m²) |
| Outer Surface Treatment | Shot-blasted to Sa 2.5 standard |
| Coatings & Finish | Vessel External: High-durability White coating (≥220μm )
Frame External: High-durability White coating (≥220 μm) |